DCA-25USIE

Specification

Model
DCA-25USIE
Rated output
Continuous
20/25kVA
Stand by
22/27.5kVA
Voltage( ) indicates options.
190~220/200~240V
(380~440/380~480V)
Power Factor
Three Phase 0.8
Engine
Isuzu BV-4LE2
Fuel
Diesel
Tank Capacity
80L
Emission Regulation
Tier 3(Japanese regulation)
Dimension L×W×H
1,550×790×1,000mm
Weight
660kg
Sound Level (From 7m)
50Hz
50dB
60Hz
54dB

Options

●Contact your supplier for non-standard requests.
●Automatic start and stop device for ATS connection.
●Three way valve for connecting external tank
●Automatic transfer swich
●Dual Voltage system
●Exaust Pipe
●Salt Corrosion protection